Bioacoustics Research Lab  Monday, October 14th, 2024
BRP Home
Publications
Projects
People
Facilities

Publications (2010 - 2019)

Selected Bioengineering Research Partnership related publications from 1952 through the present are available in pdf format. If the full pdf of a publication is available, the title will be linked. Updated: February 24, 2012.

Browse publications by decade: 1950 - 1959 | 1960 - 1969 | 1970 - 1979 | 1980 - 1989 | 1990 - 1999 | 2000 - 2009 | 2010 - 2019

On this page, jump to a specific year: 2010 2011

2011

• T. A. Bigelow, Y. Labyed,B. L. McFarlin, E. Sen-Gupta and W. D. O'Brien, Jr. Comparison of Algorithms for Estimating Ultrasound Attenuation When Predicting Cervical Remodeling in a Rat Model. Proceedings of the 2011 IEEE International Symposium on Biomedical Imaging, 883-886, 2011.

• A. J. Dapore, M. R. King, J. Harter, S. Sarwate, M. L. Oelze, J. A. Zagzebski, M. N. Do, T. J. Hall and W. D. O'Brien, Jr. Analysis of Human Fibroadenomas Using Three-Dimensional Impedance Maps. IEEE Transactions on Medical Imaging, 30, 1206-1213, 2011.

• G. Ghoshal, A. C. Luchies, J. P. Blue and M. L. Oelze. Temperature Dependent Ultrasonic Characterization of Biological Media. The Journal of the Acoustical Society of America, 130, 2203-2211, 2011.

• A. Han, R. Abuhabsah, J. P. Blue, Jr., S. Sarwate and W. D. O'Brien, Jr. Ultrasonic Backscatter Coefficient Quantitative Estimates from High-concentration Chinese Hamster Ovary Cell Pellet Biophantoms. The Journal of the Acoustical Society of America, 130, 4139-4147, 2011.

• M. T. Herd, T. J. Hall, J. Jiang, J. A. Zagzebski. Improving the Statistics of Quantitative Ultrasound Techniques with Deformation Compounding: An Experimental Study. Ultrasound in Medicine and Biology, 37, 2066-2074, 2011.

• Y. Labyed, T. A. Bigelow. A theoretical comparison of attenuation measurement techniques from backscattered ultrasound echoes. The Journal of the Acoustical Society of America, 129, 2316-2324, 2011.

• Y. Labyed, T. A. Bigelow, B. L. McFarlin. Estimate of the Attenuation Coefficient Using a Clinical Array Transducer for the Detection of Cervial Ripening in Human Pregnancy. Ultrasonics, 51, 34-39, 2011.

• R. Lavarello and M. Oelze. Quantitative Ultrasound Estimates From Populations of Scatterers with Continuous Size Distributions. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 58, 744-749, 2011.

• R. Lavarello, G. Ghoshal and M. L. Oelze. On the Estimation of Backscatter Coefficients Using Single-Element Focused Transducers. The Journal of the Acoustical Society of America, 129, 2903-2911, 2011.

• J. Mamou, A. Coron, M. L. Oelze, E. Saegusa-Beecroft, M. Hata, P. Lee, J. Machi, E. Yanagihara, P. Laugier and E. J. Feleppa. Three-Dimensional High-Frequency Backscatter and Envelope Quantification of Cancerous Human Lymph Nodes. Ultrasound in Medicine & Biology, 37, 345-357, 2011.

• E. L. Madsen, M. E. Deaner, J. Mehi. Properties of Phantom Tissue-like Polymethylpentene in the Frequency Range 20-70 MHz. Ultrasound in Medicine & Biology, 37, 1327-1339, 2011.

• M. M. McCormick, E. L. Madsen, M. E. Deaner, T. Varghese. Absolute Backscatter Coefficient Estimates of Tissue-mimicking Phantoms in the 5-50 MHz Frequency Range. The Journal of the Acoustical Society of America, 130, 737-743, 2011.

• K. Nam, I.M. Rosado-Mendez, L.A. Wirtzfeld, G. Ghoshal, A.D. Pawlicki, E.L. Madsen, R.J. Lavarello, M.L. Oelze, , J.A. Zagzebski, W.D. O'Brien, Jr., T.J. Hall. Comparison of Ultrasound Attenuation and Backscatter Estimates in Layered Tissue-Mimicking Phantoms among Three Clinical Scanners. Ultrasonic Imaging, 34(4), 209-221, 2012.

• K. Nam, J. A. Zagzebski, T. J. Hall. Simultaneous Backscatter and Attenuation Estimation Using a Least Squares Method with Constraints. Ultrasound in Medicine and Biology, 37, 2096-2104, 2011.

• K. Nam, I. M. Rosado-Mendez, L. A. Wirtzfeld, A. D. Pawlicki, V. Kumar, E. L. Madsen, G. Ghoshal, R. J. Lavarello, M. L. Oelze, T, A. Bigelow, J. A. Zagzebski, W. D. O'Brien, Jr. and T. J. Hall. Ultrasonic Attenuation and Backscatter Coefficient Estimates of Rodent-Tumor-Mimicking Structures: Comparison of Results among Clinical Scanners. Ultrasonic Imaging, 33, 233-250, 2011.

• K. Nam, I. M. Rosado-Mendez, N. C. Rupert, E. L. Madsen, J. A. Zagzebski and T. J. Hall. Ultrasound Attenuation Measurements Using a Reference Phantom with Sound Speed Mismatch. Ultrasonic Imaging, 33, 251-263, 2011.

• A. D. Pawlicki, A. J. Dapore, S. Sarwate and W. D. O'Brien, Jr. Three-Dimensional Impedance Map Analysis of Rabbit Liver. The Journal of the Acoustical Society of America, 130, EL334-EL338, 2011.

2010

• J. J. Anderson, M.-T. Herd, M. R. King, A. Haak, Z. T. Hafez, J. Song, M. L. Oelze, E. L. Madsen, J. A. Zagzebski, W. D. O'Brien, Jr. and T. J. Hall. Interlaboratory Comparison of Backscatter Coefficient Estimates for Tissue-Mimicking Phantoms. Ultrasonic Imaging, 32, 48-64, 2010.

• T. A. Bigelow. Improved Algorithm for Estimation of Attenuation Along Propagation Path Using Backscattered Echoes from Multiple Sources. Ultrasonics, 50, 496-501, 2010.

• H. Feltovich, K. Nam and T. J. Hall. Quantitative Ultrasound Assessment of Cervical Microstructure. Ultrasonic Imaging, 32, 131-142, 2010.

• G. Ghoshal and M. L. Oelze. Improved Scatterer Property Estimates from Ultrasound Backscatter Using Gate-Edge Correction and a Pseudo-Welch Technique. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 57, 2828-2832, 2010.

• J. Kemmerer, G. Ghoshal and M. L. Oelze. Quantitative Ultrasound Assessment of HIFU Induced Lesions in Rodent Liver. Proceedings of the 2010 IEEE Ultrasonics Symposium, 1396-1399, 2010.

• J. Kemmerer, S. Chang and M. L. Oelze. A New Approach for Detecting Attenuation Changes During High-Intensity Focused Ultrasound. Proceedings of the 2010 IEEE Ultrasonics Symposium, 1404-1407, 2010.

• M. R. King, J. J. Anderson, M.-T. Herd, D. Ma, A. Haak, L. A. Wirtzfeld, E. L. Madsen, J.A. Zagzebski, M. L. Oelze, T. J. Hall and William D. O'Brien, Jr. Ultrasonic Backscatter Coefficients for Weakly Scattering, Agar Spheres in Agar Phantoms. The Journal of the Acoustical Society of America, 128, 903-908, 2010.

• Y. Labyed and T. A. Bigelow. Estimating the Total Ultrasound Attenuation Along the Propagation Path by Using a Reference Phantom. The Journal of the Acoustical Society of America, 128, 3232-3238, 2010.

• R. J. Lavarello and M. L. Oelze. Scattering by an Arrangement of Eccentric Cylinders Embedded on a Coated Cylinder with Applications to Tomographic Density Imaging (L). The Journal of the Acoustical Society of America, 127, 645-648, 2010.

• R. J. Lavarello and M. L. Oelze. Assessment of the Effects of Scatterer Size Distributions on Effective Scatterer Diameter Estimates. Proceedings of the 2010 IEEE Ultrasonics Symposium, 732-735, 2010.

• P. Linden, J. R. Sanchez and M. L. Oelze. Small Lesion Detection with Resolution Enhancement Compression. Ultrasonic Imaging, 32, 16-32, 2010.

• W. Liu and J. A. Zagzebski. Trade-Offs in Data Acquisition and Processing Parameters for Backscatter and Scatterer Size Estimations. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 57, 340-352, 2010.

• A. Luchies, G. Ghoshal, W. D. O'Brien, Jr. and M.L. Oelze. Reducing the Effects of Specular Scatterers on QUS Imaging Using the Generalized Spectrum. Proceedings of the 2010 IEEE Ultrasonics Symposium, 728-731, 2010.

• J. Mamou, A. Coron, M. L. Oelze, E. Saegusa-Beecroft, M. Hata, J. Machi, E. Yanagihara, P. Laugier and E. J. Feleppa. Three-Dimentional High-Frequency Spectral and Envelope Quantification of Excised Human Lymph Nodes. Proceedings of the 2010 IEEE Ultrasonics Symposium, 604-607, 2010.

• B. L. McFarlin, T. A. Bigelow, Y. Labyed, W. D. O'Brien, Jr. and M. L. Oelze. Ultrasonic Attenuation Estimation of the Pregnant Cervix: A Preliminary Report. Ultrasound in Obstetrics and Gynecology, 36, 218-225, 2010.

• M. Teisseire, A. Han, R. Abuhabsah, J. P. Blue, Jr., S. Sarwate and W. D. O'Brien, Jr. Ultrasonic Backscatter Coefficient Quantitative Estimates from Chinese Hamster Ovary Cell Pellet Biophantoms. The Journal of the Acoustical Society of America, 128, 3175-3180, 2010.

• L. A. Wirtzfeld, G. Ghoshal, Z. T. Hafez, K. Nam, Y. Labyed, J. J. Anderson, M. - T. Herd, A. Haak, Z. He, R. J. Miller, S. Sarwate, D. G. Simpson, J. A. Zagzebski, T. A. Bigelow, M. L. Oelze, T. J. Hall, W. D. O'Brien, Jr. Cross-Imaging Platform Comparison of Ultrasonic Backscatter Coefficient Measurements of Live Rat Tumors. Journal of Ultrasound in Medicine, 29, 1117-1123, 2010.

Back to Top